A COMBINATION OF COGENERATION, EVAPORATION AND MEMBRANE TECHNIQUE FOR LANDFILL LEACHATE TREATMENT

Landfill leachate treatment is an actual point of interest for many landfills managers mainly due to the regulations that are changing in several countries and that impose more restrictions. Traditionally there are several types of techniques applied to landfill leachate treatment:
- Evaporation
- Membranes techniques;
- Biological treatment
- Chemical-physical treatment.

The paper presents a solution realised to solve the problem of treatment of landfill leachate in a site in the north of Paris where two landfills are present: an old closed one and a new one still in operation. Two different types of treatment have been chosen to adapt the solution to the specific characteristics of the two different leachates: Reverse osmosis for the old stable leachate and double stage evaporation coupled with the LFG engines to improve the energetic efficiency of motors on MSW landfill, for the new changing leachate. The paper will describe the dimensioning data, the performances of the plant and the results obtained after one year operation of one installation chosen among about 10 other working plants. An economical evaluation of the Operative costs will be reported too.



Copyright: © IWWG International Waste Working Group
Quelle: Specialized Session E (Oktober 2007)
Seiten: 12
Preis inkl. MwSt.: € 12,00
Autor: E. Giust
D. Visintin
C. Del Piccolo

Artikel weiterleiten In den Warenkorb legen Artikel kommentieren


Diese Fachartikel könnten Sie auch interessieren:

CLONIC: CLOSING THE NITROGEN CYCLE FROM LANDFILL LEACHATES. A BIOLOGICAL PROCESS WITH PARTIAL NITRITATION AND ANAMMOX FOLLOWED BY THERMAL DRY TREATMENT.
© IWWG International Waste Working Group (10/2007)
CESPA, being part of the Ferrovial Group, is a leader in waste management and urban services in Spain. CESPA has a long experience in landfill construction and management, having a total of 37 landfills either in property or in exploitation. As one of the legal and environmental requirements, a suitable leachate treatment must be applied before the discharge to the receiving media. Thus, the decision to choose for an specific leachate treatment depends on different parameter such as: the landfill site location, physical location of the leachate treatment plant, the leachate quality, the discharge requirements and the best technologies available.

EMISSIONS MEASUREMENT AND GAS CAPTURE FROM A HORIZONTAL PLANE BASED GAS COLLECTION SYSTEM
© IWWG International Waste Working Group (10/2007)
In an effort to increase waste biodegradation rates, landfill operators in the United States have been actively recirculating leachate and pursuing bioreactor landfill practices that utilize additional liquids from outside sources to increase the moisture content of the waste. The preferred waste moisture content range of these advanced sanitary waste cells is 35% to 45% (wet weight basis). Historically, U.S. landfills have used vertical gas well systems for the recovery of landfill gas. With the onset of over 150 leachate recirculation projects in the U.S. and over 20 bioreactor landfills, an increase in maintenance costs in the vertical well fields and a potential for increased surface emissions have been noted. The classic vertical well systems have been filling with leachate. This has resulted in the need for the installation of automatic pump out systems and an increased frequency of maintenance to reduce surface emissions.

bifa-Text Nr. 57: Die Abfallwirtschaft im Jahr 2030 - Eine Szenarioanalyse nicht nur für Bayern
© bifa Umweltinstitut GmbH (5/2012)
In einer neuen Studie des bifa Umweltinstituts werden mögliche Entwicklungen der regionalen, nationalen und internationalen Rahmenbedingungen für die bayerische Abfallwirtschaft im Jahr 2030 dargestellt sowie deren Auswirkungen auf die Abfallwirtschaftsstrukturen und auf die Ökoeffizienz. Das Projekt wurde im Auftrag des Bayerischen Staatsministeriums für Umwelt und Gesundheit durchgeführt. Die Ergebnisse bieten auch anderen Behörden, Unternehmen und Verbänden in Deutschland eine Basis für die eigene Positionierung und Strategieentwicklung.

Optimierung der Deponieentgasung: Erfahrungen mit tiefenverfilterten neuen und modifizierten vorhandenen Gasbrunnen
© LGA Bautechnik GmbH (9/2009)
Was versteht man unter tiefenverfilterten Gasbrunnen? Die Antwort ergibt sich schon aus dem Wort selbst. Die Verfilterung beginnt erst in größerer Tiefe. Gasbrunnen im Deponiebereich werden normalerweise als 600 –800 mm Brunnen mit einer Filterstrecke bis 2 oder 3 m unter GOK errichtet. Bei nicht oberflächengedichteten Deponien endet somit die Filterstrecke kurz unterhalb einer mehr oder weniger starken und auch mehr oder weniger, meist mehr, gut gasgängigen Abdeckung.

Mai-Fest für den Umweltschutz - IFAT 2008 in München
© Deutscher Fachverlag (DFV) (5/2008)
Internationaler und größer - die IFAT 2008. Zur weltweit bedeutendsten Messe für Wasser, Abwasser, Abfall und Recycling werden vom 5. bis 9. Mai in München mehr als 100.000 Besucher erwartet. Für sie gibt es mit rund 2.500 Ausstellern ein noch breiteres Angebot als vor drei Jahren.

Name:

Passwort:

 Angemeldet bleiben

Passwort vergessen?

SCHNELL Motoren AG
Erneuerbaren Energien gehört die
Zukunft: Blockheizkraftwerke
für Energie aus Biomasse