Treatability studies for an organized industrial district (OID) effluent in Bursa, Turkiye for agricultural irrigation purposes

The reusability of the effluent from the wastewater treatment plant of an organized industrial district in the northwest of Turkiye was investigated in this study. Chemical precipitation and ion exchange methods were used to obtain a water reusable for agricultural irrigation purposes.

Optimum removal efficiencies for suspended solid (SS) and chemical oxygen demand (COD) were obtained as 96% and 31%, when the pH value was adjusted to 11 in the chemical precipitation process. The average removal efficiencies obtained for conductivity, SO4-2  and Cl- were 95 %, 71 % and 96 %, respectively, when the resin with 20mL H+ type/20mL OH- type ratio was used in the ion exchange process. As a result of the study, the effluent from the organized industrial district was found to be reusable for agricultural irrigation purposes.



Copyright: © Aristotle University of Thessaloniki
Quelle: 2nd International Conference 2009 (Juni 2009)
Seiten: 6
Preis inkl. MwSt.: € 5,00
Autor: S. K. A. Solmaz
Dr. G. E. Üstün
F. Ciner

Artikel weiterleiten In den Warenkorb legen Artikel kommentieren


Diese Fachartikel könnten Sie auch interessieren:

Probenahme- und Analyseverfahren zur kostengünstigen Überwachung von Arzneimittelwirkstoffen im Abwasser
© DIV Deutscher Industrieverlag GmbH (6/2011)
Fachbeitrag zum vom BMWi geförderten Forschungsprojekt der GBA Gesellschaft für Bioanalytik Hamburg mbH

Spurenstoffentfernung mit elektrokatalytisch erzeugten Hydroxylradikalen
© BIUKAT - Bayerisches Institut für Umwelt- und Kläranlagentechnologie e.V. (3/2010)
In Deutschland wurden in den letzten Jahrzehnten enorme Fortschritte in der Abwasserreinigung erreicht. So konnten gegenüber den 80er-Jahren die Emissionen der Kläranlagen laut DWA um mehr als 80 Prozent bei den Phosphorverbindungen und um mehr als 60 Prozent bei den Stickstoffverbindungen reduziert werden. Diese gezielte und effektive Eliminierung von Nährstoffen führte zu einer stabilen und nachhaltigen Gewässerqualität in den Vorflutern.

Treatment and control of industrial waste water effluents containing hexavalent chromium
© Aristotle University of Thessaloniki (6/2009)
In this work the method for the treatment of industrial waste waters effluents containing hexavalent chromium in three companies during process of treating metal surface with chromic acid is described.

Wenn jeder Tropfen zählt - Singapur – globales Zentrum für nachhaltiges Wasser-Management
© Deutscher Fachverlag (DFV) (7/2007)
Mangels eigener Quellen setzt Singapur auf eine viergleisige Strategie, in deren Mittelpunkt die Schließung des Wasserkreislaufs steht. Im Zuge der Umsetzung entwickelt sich der asiatische Tigerstaat zum internationalen Zentrum für nachhaltige Wasser-Technologien.

Bemessungsansatz für Pflanzenkläranlagen im Mischsystem - Abwasserbehandlung, Pflanzenkläranlage, DWA – A 262, Mischwasser, Bemessung,
© DIV Deutscher Industrieverlag GmbH (3/2007)
Im Saarland ist vom Entsorgungsverband Saar ein genehmigungsfähiges Konzept zur Behandlung von Mischwasser in Pflanzenkläranlagen entwickelt worden. Es stellt sich hier dem DWA-Arbeitsblatt A 262 (2006).

Name:

Passwort:

 Angemeldet bleiben

Passwort vergessen?